NSN: 5950-00-653-8176

Coils and Transformers

TRANSFORMER ASSEMBLY

5950 - Coils and Transformers

TRANSFORMER ASSEMBLY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.112 inches single group

  • Overall Height

    0.969 inches maximum

  • Winding Operating Voltage

    16.00 ac pounds per hour wet all components single primary input

  • Terminal Type And Quantity

    9 wire hook

  • Winding Operating Voltage

    78.00 ac pounds per hour wet all components single primary output

  • Overall Length

    3.688 inches maximum

  • Mounting Method

    threaded hole single group

  • Thread Class (Non-Core)

    2b single group

  • Thread Direction (Non-Core)

    right-hand single group

  • Winding Operating Current

    20.0 milliamperes nominal b all components single primary output

  • Rating Method

    electrical all components single primary input

  • Inclosure Type

    fully inclosed

  • Unpackaged Unit Weight (Non-Core)

    12.800 ounces

  • Rating Method

    electrical all components single primary output

  • Overall Width

    1.469 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.109 inches minimum single mounting facility single center group and 1.141 inches maximum single mounting facility single center group

  • Maximum Operating Temp

    105.0 deg celsius

  • Dc Resistance Rating In Ohms

    6.100 all components single primary input

  • Component Name And Quantity (Non-Core)

    3 transformer

  • Test Data Document

    10001-1981447 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Reliability Indicator

    not established

  • Input-Output Phase Relationship

    single phase to single phase all components

  • Frequency Rating

    400.0 hertz nominal all components

  • Thread Series Designator

    unc single group

  • Winding Function And Quantity

    1 primary, fixed autotransformer type all components

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.734 inches minimum single mounting facility single center group and 0.766 inches maximum single mounting facility single center group

  • Winding Power Rating

    1.6 volts-amperes all components single primary output

  • Dc Resistance Rating In Ohms

    74.000 all components single primary output

  • Mounting Facility Quantity

    4 single group

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...