NSN: 5950-00-978-6638
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Operating Temp
95.0 deg celsius
-
Winding Operating Voltage
12.60 ac volts nominal single component 2nd secondary
-
Body Width
1.240 inches minimum and 1.310 inches maximum
-
Winding Operating Voltage
42.60 ac volts nominal single component single primary
-
Frequency Rating
450.0 hertz nominal single component
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Current
3.0 milliamperes ac maximum single component 1st secondary
-
Mounting Hole Diameter
0.189 inches nominal single group
-
Terminal Type And Quantity
8 solder stud
-
Mounting Method
unthreaded hole single group
-
Reliability Indicator
not established
-
Winding Operating Current
3.0 milliamperes ac maximum single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Mounting Facility Quantity
1 single group
-
Body Length
0.810 inches minimum and 0.880 inches maximum
-
Winding Operating Voltage
3.50 ac volts nominal single component 1st secondary