NSN: 5950-01-035-5725
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
17.00 ac volts nominal single component 2nd secondary
-
Winding Operating Current
600.0 milliamperes ac maximum single component 2nd secondary
-
Body Height
1.600 inches nominal
-
Body Width
1.200 inches nominal
-
Mounting Facility Quantity
2 single group
-
Mounting Hole Diameter
0.149 inches nominal single group
-
Mounting Method
flange single group and unthreaded hole single group
-
Inclosure Type
fully inclosed
-
Winding Operating Current
100.0 milliamperes ac maximum single component 1st secondary
-
Distance Between Mounting Facility Centers
2.400 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Shielding Method
internal shield grounded to core single component
-
Body Length
2.100 inches nominal
-
Terminal Type And Quantity
10 wire lead
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Voltage
31.60 ac volts nominal single component 1st secondary
-
Overall Length
2.600 inches nominal
-
Winding Operating Current
30.0 milliamperes ac maximum single component 3rd secondary
-
Winding Operating Voltage
158.50 ac volts nominal single component 3rd secondary