NSN: 5950-01-302-3330
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
24 turret
-
Body Width
2.320 inches maximum
-
Winding Operating Voltage
1.19 ac minor wet single component 2nd secondary
-
Winding Operating Voltage
200.00 ac pounds per hour wet single component single primary
-
Test Data Document
97942-593r819 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
End Item Identification
f-16 adf radar
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
0.350 inches nominal 2nd mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To The Base Of An Isosceles Triangle
1.570 inches nominal 2nd mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.940 inches nominal 1st mounting facility single center group
-
Body Height
3.980 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Hole Diameter
0.147 inches nominal 2nd group
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Voltage
123.00 ac pounds per hour wet single component 3rd secondary
-
Mounting Facility Quantity
3 2nd group
-
Mounting Method
unthreaded hole all groupings
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Mounting Hole Diameter
0.191 inches nominal 1st group
-
Maximum Operating Temp
70.0 deg celsius
-
Winding Operating Voltage
2.33 ac minor wet single component 1st secondary
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Transformer Winding Connection Type
delta-delta and delta-wye
-
Mounting Facility Quantity
4 1st group
-
Body Length
5.570 inches maximum
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Current
245.0 milliamperes nominal b single component 1st secondary
-
Winding Operating Current
270.0 milliamperes nominal b single component 3rd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.790 inches nominal 1st mounting facility single center group
-
Winding Operating Current
91.0 milliamperes nominal b single component 2nd secondary
Related Parts by Category
Related Manufacturers


AS6081 Methods