NSN: 5950-01-318-6661

Coils and Transformers

TRANSFORMER ASSEMBLY

5950 - Coils and Transformers

TRANSFORMER ASSEMBLY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Operating Voltage

    74.10 ac pounds per hour wet 1st component 2nd secondary and 70.90 ac pounds per hour wet 1st component 2nd secondary and 78.55 ac pounds per hour wet 1st component 2nd secondary and 41.50 ac pounds per hour wet 1st component 2nd secondary and 38.30 ac

  • ~1

    pounds per hour wet 1st component 2nd secondary

  • Winding Power Rating

    2.56 volts-amperes 2nd component 3rd secondary

  • Dc Resistance Rating In Ohms

    0.7932 2nd component 1st secondary

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.730 inches minimum single mounting facility single center group and 1.770 inches maximum single mounting facility single center group

  • Overall Length

    2.390 inches minimum and 2.430 inches maximum

  • Dc Resistance Rating In Ohms

    0.0886 1st component 1st secondary

  • Winding Function And Quantity

    1 primary 2nd component and 4 secondary 2nd component

  • Reliability Indicator

    not established

  • Dc Resistance Rating In Ohms

    4.300 2nd component 3rd secondary

  • Winding Operating Current

    100.0 milliamperes nominal b 2nd component 4th secondary

  • Winding Power Rating

    19.44 volts-amperes 1st component 1st secondary

  • Input-Output Phase Relationship

    single phase to single phase all components

  • Terminal Type And Quantity

    30 turret

  • Frequency Rating

    400.0 hertz nominal all components

  • Winding Tap Location (Non-Core)

    multiple taps w/center tap 1st component 2nd secondary

  • Winding Operating Voltage

    115.00 ac pounds per hour wet all components single primary

  • Rating Method

    electrical all components all secondary

  • Winding Operating Voltage

    159.70 ac pounds per hour wet 2nd component 2nd secondary

  • Winding Operating Current

    15.0 milliamperes nominal b 2nd component 2nd secondary

  • Mounting Facility Quantity

    4 single group

  • Winding Operating Voltage

    56.90 ac pounds per hour wet 2nd component 1st secondary and 14.70 ac pounds per hour wet 2nd component 1st secondary and 71.60 ac pounds per hour wet 2nd component 1st secondary

  • Winding Tap Location (Non-Core)

    center tap 2nd component 2nd secondary

  • Winding Function And Quantity

    1 primary 1st component and 2 secondary 1st component

  • Winding Operating Voltage

    24.30 ac pounds per hour wet 1st component 1st secondary

  • Overall Height

    5.068 inches minimum and 5.088 inches maximum

  • Winding Operating Voltage

    25.60 ac pounds per hour wet 2nd component 3rd secondary

  • Test Data Document

    16340-11-00151 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Dc Resistance Rating In Ohms

    0.700 all components single primary

  • Winding Operating Voltage

    26.20 ac pounds per hour wet 2nd component 4th secondary

  • Winding Operating Current

    1.7 amperes nominal b all components single primary

  • Winding Tap Location (Non-Core)

    multiple taps w/center tap 2nd component 1st secondary

  • Winding Power Rating

    195.5 volts-amperes all components single primary

  • Overall Width

    2.117 inches minimum and 2.217 inches maximum

  • Winding Operating Current

    800.0 milliamperes nominal b 1st component 1st secondary

  • Winding Operating Current

    640.0 milliamperes nominal b 2nd component 1st secondary

  • Rating Method

    electrical all components single primary

  • Maximum Operating Temp

    104.0 deg celsius

  • Winding Power Rating

    44.96 volts-amperes 1st component 2nd secondary

  • Dc Resistance Rating In Ohms

    52.200 2nd component 2nd secondary

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    1.410 inches minimum single mounting facility single center group and 1.450 inches maximum single mounting facility single center group

  • Dc Resistance Rating In Ohms

    7.800 1st component 2nd secondary

  • Winding Power Rating

    2.4 volts-amperes 2nd component 2nd secondary

  • Maximum Transformer Power Rating

    195.5 volt-ampere all components

  • Winding Tap Location (Non-Core)

    center tap 1st component 1st secondary

  • Mounting Method

    slot single group

  • Winding Power Rating

    2.62 volts-amperes 2nd component 4th secondary

  • Winding Operating Current

    75.0 milliamperes nominal b and better 1st component 2nd secondary and 400.0 milliamperes nominal b and better drop siding 1st component 2nd secondary

  • Mounting Slot Width

    0.115 inches minimum single group and 0.135 inches maximum single group

  • Winding Power Rating

    45.824 volts-amperes 2nd component 1st secondary

  • Inclosure Type

    fully inclosed

  • Component Name And Quantity (Non-Core)

    2 transformer

  • Dc Resistance Rating In Ohms

    0.540 2nd component 4th secondary

  • Winding Operating Current

    100.0 milliamperes nominal b 2nd component 3rd secondary

  • Winding Shielding Method

    internal shield brought out to terminal all components

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...