NSN: 5990-00-111-8601

Synchros and Resolvers

SYNCHRO,CONTROL TRANSFORMER

  • No manufacturer data was found.

5990 - Synchros and Resolvers

SYNCHRO,CONTROL TRANSFORMER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Shoulder Length

    0.0620 nominal inches

  • Rotor Dc Resistance In Ohms

    385.00 nominal

  • Zro Impedance Magnitude In Ohms

    3340.00 nominal

  • Mounting Surface To Terminal End Distance

    1.7340 inches maximum

  • Stator Input Electrical Power Rating

    30.0 milliwatts nominal

  • Pilot Length

    0.0620 nominal inches

  • Shaft Maximum Runout

    0.0014 inches

  • Transformation Ratio

    2.203 rotor to stator nominal

  • Undercut Diameter

    0.9750 inches nominal

  • Shaft Length

    0.3120 inches nominal single shaft

  • Undercut Width

    0.0500 inches nominal

  • Terminal Location

    rear

  • Pilot Diameter

    0.6250 inches maximum

  • Actuator Friction Torque At Minus 55 Deg Celsius

    16.0 centimeter-grams nominal

  • Phase Shift Angle In Deg

    4.200 output to input nominal

  • Maximum Fundamental Null Voltage In Millivolts Per Volt

    25.00 input

  • Stator Input Voltage Rating In Volts

    11.8 nominal

  • Shoulder Diameter

    1.0000 inches maximum

  • Shaft Type

    round, slotted single shaft

  • Frequency In Hertz

    400.0 nominal

  • Shaft Slot Depth

    0.0300 inches nominal single shaft

  • Shaft Radial Play Determining Weight

    4.0 ounces

  • Shaft Slot Width

    0.0250 inches nominal single shaft

  • Flange Thickness

    0.0930 inches nominal

  • Body Material

    steel, stainless

  • Terminal Type And Quantity

    5 wire lead

  • Overall Length

    2.1840 inches maximum

  • Body Size

    11

  • Schematic Diagram Designator

    err-090

  • Actuator Friction Torque At Plus 25 Deg Celsius

    4.0 centimeter-grams nominal

  • Shaft Maximum Radial Play

    0.0010 inches

  • Zrs Impedance Magnitude In Ohms

    659.00 nominal

  • Shaft End Play

    0.0005 inches minimum and 0.0015 inches maximum

  • Zso Impedance Angle In Deg

    80.70 nominal

  • Shaft End Play Determining Weight

    16.0 ounces

  • Stator Input Current Rating

    21.0 milliamperes maximum

  • Zro Impedance Angle In Deg

    79.20 nominal

  • Maximum Total Null Voltage Output In Millivolts Per Volt

    30.00

  • Stator Dc Resistance In Ohms

    60.00 nominal

  • Zrs Impedance Angle In Deg

    30.10 nominal

  • Zso Impedance Magnitude In Ohms

    577.00 nominal

  • Body Style

    standard round c

  • Flange Diameter

    1.0620 inches nominal

  • Electrical Error Angular Range In Minutes

    -2.0/+2.0

  • Shaft Diameter

    0.1200 inches maximum single shaft

  • Shaft Radial Play Test Point

    0.125 inches maximum

Related Parts by Category

No related parts.

Related Manufacturers

No related manufacturers.

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...