E17-0120

Circuit Breakers

CIRCUIT BREAKER

E17-0120

5925-00-496-3826

5925 - Circuit Breakers

Liebert Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    225.0 amperes ac all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    4.876 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Length

    6.562 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.876 inches nominal

  • Boss Height

    0.187 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Body Height

    2.625 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 maximum at 200 pct all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...