1922-062

Circuit Breakers

CIRCUIT BREAKER

1922-062

5925-00-888-1380

5925 - Circuit Breakers

Jaidinger Mfg. Co. Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    175.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    8.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Body Height

    4.375 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 rotary

  • Boss Height

    0.250 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Body Length

    9.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...