77C701590P001

Filters and Networks

FILTER,BAND PASS

77C701590P001

5915-00-995-4759

5915 - Filters and Networks

Hisonic Inc.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Discrimination At Specified Frequencies Per Function In Decibels

    20.0 minimum 4th band pass and 3.0 maximum 4th band pass and 3.0 maximum 4th band pass and 20.0 minimum 4th band pass

  • Frequency Band Width Per Function

    280.00 hertz 4th band pass and 300.00 hertz 4th band pass

  • Specified Frequencies Of Discrimination Per Function

    300.00 hertz 6th band pass and 280.00 hertz 6th band pass and 320.00 hertz 6th band pass and 340.00 hertz 6th band pass

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 4th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 4th band pass

  • Input Impedance Per Function W/load

    600.0 ohms 1st band pass

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 5th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 5th band pass

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 6th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 6th band pass

  • Reference Frequency Per Function

    300.0 single high pass three phase to two phase

  • Functional Terminal Type And Quantity

    2 tab, solder lug ground 3rd function

  • Body Height

    5.250 inches maximum

  • Input Impedance Per Function W/load

    600.0 ohms 2nd band pass

  • Mounting Facility Screw Thread Series Designator

    unc

  • Frequency Band Width Per Function

    260.00 hertz 2nd band pass and 280.00 hertz 2nd band pass

  • Frequency Band Width Per Function

    300.00 hertz 6th band pass and 320.00 hertz 6th band pass

  • Special Features

    15 functions

  • Input Impedance Per Function W/load

    600.0 ohms 3rd band pass

  • Reference Frequency Per Function

    270.0 single high pass two phase to two phase

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    4.625 inches nominal

  • Frequency Band Width Per Function

    290.00 hertz 5th band pass and 310.00 hertz 5th band pass

  • Functional Terminal Type And Quantity

    8 tab, solder lug output 2nd function

  • Frequency Band Width Per Function

    250.00 hertz 1st band pass and 270.00 hertz 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 1st band pass

  • Nominal Thread Size

    0.375 inches

  • Body Material

    metal

  • Specified Frequencies Of Discrimination Per Function

    260.00 hertz 2nd band pass and 240.00 hertz 2nd band pass and 280.00 hertz 2nd band pass and 300.00 hertz 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    20.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 20.0 minimum 1st band pass

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    250.00 hertz 1st band pass and 270.00 hertz 1st band pass and 230.00 hertz 1st band pass and 290.00 hertz 1st band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    22.5 3rd band pass

  • Body Width

    5.750 inches maximum

  • Reference Frequency Per Function

    290.0 single high pass hertz

  • Overall Height

    5.950 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    290.00 hertz 5th band pass and 310.00 hertz 5th band pass and 270.00 hertz 5th band pass and 330.00 hertz 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 3rd band pass and 20.0 minimum 3rd band pass and 3.0 maximum 3rd band pass and 20.0 minimum 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 5th band pass and 3.0 maximum 5th band pass and 20.0 minimum 5th band pass and 20.0 minimum 5th band pass

  • Inclosure Type

    encased

  • Discrimination At Specified Frequencies Per Function In Decibels

    20.0 minimum 6th band pass and 3.0 maximum 6th band pass and 3.0 maximum 6th band pass and 20.0 minimum 6th band pass

  • Output Impedance Per Function W/source Across Input

    34.0 kilohms 1st band pass

  • Frequency Band Width Per Function

    270.00 hertz 3rd band pass and 290.00 hertz 3rd band pass

  • Reference Frequency Per Function

    260.0 single high pass pulses per second

  • Specified Frequencies Of Discrimination Per Function

    250.00 hertz 3rd band pass and 270.00 hertz 3rd band pass and 290.00 hertz 3rd band pass and 310.00 hertz 3rd band pass

  • Input Impedance Per Function W/load

    600.0 ohms 4th band pass

  • Reference Frequency Per Function

    280.0 single high pass two phase to three phase

  • Input Impedance Per Function W/load

    600.0 ohms 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    20.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass

  • Functional Terminal Type And Quantity

    7 tab, solder lug input 1st function

  • Input Impedance Per Function W/load

    600.0 ohms 6th band pass

  • Unpackaged Unit Weight

    20.000 pounds

  • Reference Frequency Per Function

    310.0 single high pass gigahertz

  • Specified Frequencies Of Discrimination Per Function

    280.00 hertz 4th band pass and 300.00 hertz 4th band pass and 260.00 hertz 4th band pass and 320.00 hertz 4th band pass

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Operating Temp Range

    +15.0/+55.0 deg celsius

  • Body Length

    6.500 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...