076R100

Switches

SWITCH,THERMOSTATIC

076R100

5930-01-075-8608

5930 - Switches

A R E Mfg Co Inc

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Hazardous Locations/environmental Protection

    dustproof

  • Body Height

    1.437 inches maximum

  • Overall Length

    2.380 inches nominal

  • Mounting Method

    bracket and threaded hole

  • Mounting Facility Pattern

    two position in-line

  • Bulb Diameter

    0.375 inches nominal

  • Contact Action Stimulus

    increase

  • Contact Load Current Rating

    96.0 amperes resistive load first voltage and 20.0 amperes inductive load first voltage

  • Temp Sensing Element Type

    capillary tube-bulb

  • Contact Adjustability

    deactuation point adjustable and actuation point adjustable

  • Contact Voltage Rating In Volts

    240.0 ac at sea level first voltage

  • Contact Load Current Rating

    96.0 amperes resistive load second voltage and 20.0 amperes inductive load second voltage

  • Capillary Tube Length

    30.2 inches nominal

  • Contact Adjustment Range

    +68.00/+97.00 actuation point degrees fahrenheit and +60.00/+97.00 deactuation point degrees fahrenheit

  • Thread Quantity Per Inch

    32 all threaded hole

  • Operating Temp Rating

    250.0 deg fahrenheit maximum

  • Contact Adjustment Type

    external deactuation point shaft with scale and external actuation point shaft with scale

  • Distance Between Mounting Facility Centers

    1.250 inches nominal

  • Overall Height

    2.437 inches nominal

  • Media For Which Designed

    gas

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Overall Width

    1.215 inches maximum

  • End Item Identification

    air condition 57107

  • Thread Class

    2b all threaded hole

  • Bulb Length

    1.375 inches nominal

  • Thread Series Designator

    unc all threaded hole

  • Nominal Thread Size

    0.164 inches all threaded hole

  • Terminal Type

    screw

  • Contact Voltage Rating In Volts

    120.0 ac at sea level second voltage

  • Style Designator

    rectangular

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...