209-2-24098-1

Circuit Breakers

CIRCUIT BREAKER

209-2-24098-1

5925-01-367-8661

5925 - Circuit Breakers

Airpax Corp Llc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • External Actuator Linkage Arrangement

    one and two linked

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac second location

  • Terminal Type And Quantity

    4 threaded stud

  • Boss Height

    0.220 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc second location

  • Manual Actuator Type And Quantity

    2 toggle

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.072 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes dc first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 110.000 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Length

    5.125 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc first location

  • Reset Method

    manual

  • Frequency In Hertz

    50.0 second location or 60.0 second location

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...