NSN: 5915-00-486-7050

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Functional Terminal Type And Quantity

    1 tab, solder lug input 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance blank

  • Functional Terminal Type And Quantity

    1 tab, solder lug output 2nd function

  • Reference Frequency Per Function

    22.0 kilohertz blank

  • Body Length

    0.734 inches maximum

  • Style Designator

    rectangular terminal/terminals on one surface

  • Body Width

    0.734 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.562 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum blank and 3.0 maximum blank and 40.0 minimum blank and 40.0 minimum blank

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 blank

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.112 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.562 inches nominal

  • Source Impedance Rating Per Function

    100.0 kilohms blank

  • Test Data Document

    10001-2641158 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Load Impedance Per Function

    100.0 kilohms blank

  • Functional Terminal Type And Quantity

    1 tab, solder lug ground 3rd function

  • Overall Height

    1.781 inches maximum

  • Frequency Band Width Per Function

    20.35 kilohertz blank and 23.65 kilohertz blank

  • Maximum Dielectric Withstanding Ac Rms Voltage

    500.0 volts at sea level

  • Operating Temp Range

    +0.0/+50.0 deg celsius

  • Body Height

    1.406 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    12.54 kilohertz blank and 23.65 kilohertz blank and 20.35 kilohertz blank and 38.50 kilohertz blank

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...