NSN: 5915-00-846-0829

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Temp Range

    +0.0/+70.0 deg celsius

  • Load Impedance Per Function

    33.0 kilohms blank

  • Specified Frequencies Of Discrimination Per Function

    3.295 kilohertz blank and 3.695 kilohertz blank and 1.499 kilohertz blank and 5.495 kilohertz blank

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.500 inches nominal

  • Style Designator

    rectangular terminal/terminals on one surface

  • Insertion Loss At Reference Frequency Per Function In Decibels

    12.0 blank

  • Vibration Resistance Range In Hertz

    +10.0/+55.0

  • Principal Circuitry Type Per Function

    inductance-resistance blank

  • Body Length

    3.000 inches nominal

  • Average Life Rating In Hours

    10000.0

  • Functional Terminal Type And Quantity

    2 tab, solder lug input 1st function

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.164 inches

  • Source Impedance Rating Per Function

    33.0 kilohms blank

  • Functional Terminal Type And Quantity

    1 tab, solder lug ground 3rd function

  • Output Impedance Per Function W/source Across Input

    33.0 kilohms blank

  • Body Width

    2.000 inches nominal

  • Reference Frequency Per Function

    3.495 kilohertz blank

  • Maximum Dielectric Withstanding Ac Rms Voltage

    500.0 volts at sea level

  • Inclosure Type

    hermetically sealed

  • Body Height

    2.250 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    60.0 minimum blank and 3.0 maximum blank and 3.0 maximum blank and 60.0 minimum blank

  • Overall Height

    3.000 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Functional Terminal Type And Quantity

    2 tab, solder lug output 2nd function

  • Frequency Band Width Per Function

    3.295 kilohertz blank and 3.695 kilohertz blank

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Input Impedance Per Function W/load

    33.0 kilohms blank

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...