NSN: 5925-01-056-6257

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Body Length

    6.312 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.812 inches nominal

  • Boss Height

    0.150 inches nominal

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Circuit Protection Type

    overcurrent second location

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    4.125 inches nominal

  • Body Height

    4.094 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.812 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Pole Quantity

    3

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Circuit Protection Type

    overcurrent first location

  • Circuit Protection Type

    undervoltage third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 screw

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    6.0 ac

  • Switch Voltage Rating And Type In Volts

    480.0 ac

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...