NSN: 5925-01-058-1265

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349--83383/02-09 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location and 50.0 amperes dc single location

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Unpackaged Unit Weight

    0.750 pounds

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Overall Length

    3.250 inches maximum

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • ~1

    type data on certain environmental and performan

  • Mounting Surface To Terminal End Distance

    4.260 inches maximum

  • Pole Quantity

    1

  • Unthreaded Mounting Hole Diameter

    0.167 inches minimum and 0.177 inches maximum

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.940 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3600.0 ac single location and 3600.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    13.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Specification/standard Data

    81349-mil-c-83383/2 government specification

  • Switch Current Rating And Type In Amps

    3.0 ac and 3.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Body Width

    1.200 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...