NSN: 5925-01-118-7438

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1b multipole-single actuator type

  • Body Length

    2.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Iii Nonturn Device Location

    at 12 oclock and at 3 oclock and at 9 oclock

  • Iii Nonturn Device Length

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    3

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Iii Unpackaged Unit Weight

    9.000 ounces

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    6 tab w/screw

  • Thread Pitch Diameters

    0.4752 to 0.4787 inches

  • Bushing Length

    0.625 inches nominal

  • Body Width

    2.250 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Iii Nonturn Device Radius

    0.656 inches nominal

  • Iii Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 150.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Frequency In Hertz

    50.0 or 60.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...