NSN: 5925-01-183-6633

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1d rectangular dimensional envelope

  • Overall Height

    1.256 inches maximum

  • Overall Width

    2.920 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • End Item Identification

    helicopter application; 5925-01-183-6633

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac single location and 25.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    instantaneous single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip w/remote trip feature single location

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Switch Terminal Type

    turret

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Frequency In Hertz

    400.0 single location

  • Terminal Type And Quantity

    2 threaded stud

  • Overall Length

    3.250 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.167 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3600.0 ac single location and 3600.0 dc

  • Trip Release Method

    thermal single location

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    28.0 dc nominal single location

  • Reset Method

    electric

  • Actuator Function

    trip w/separate reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Release Duty Cycle

    continuous single location

  • Switch Location And Position Designation

    internal at pole one

  • Reset Actuator Voltage Rating And Type In Volts

    115.0 ac

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...