NSN: 5925-01-294-5707

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance re

  • Specification/standard Data

    81348-w-c-375/11 government specification

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac all locations and 80.0 amperes dc all locations

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Terminal Type And Quantity

    4 compression

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Overall Width

    4.156 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 125.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac all locations and 5000.0 dc all locations

  • Body Style

    rectangular dimensional envelope

  • Pole Quantity

    2

  • Trip Delay Time In Seconds Per Rated Continuous Current

    100.000 minimum at 200 pct all locations and 190.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Overall Length

    6.312 inches nominal

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.187 inches nominal

  • Overall Height

    2.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...