TEF124030-02295
Circuit Breakers
CIRCUIT BREAKER
TEF124030-02295
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes ac single location and 30.0 amperes dc single location 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Body Length6.312 inches nominal 
- 
                                    Trip Release Characteristicinstantaneous all locations and time delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.375 inches nominal 
- 
                                    Body Width2.750 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.380 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Trip Release Methodthermal-magnetic all locations 
- 
                                    Trip Release Ambient Temp Rating50.0 deg celsius nominal all locations 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts480.0 ac single location and 250.0 dc single location 
- 
                                    Mounting Slot Width0.188 inches nominal 
- 
                                    Terminal Type And Quantity4 compression 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.880 inches nominal 
- 
                                    Arc Quenching Methoddeion 
- 
                                    Mounting Facility Type And Quantity4 slot and 2 unthreaded hole 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Boss Height0.125 inches nominal 
- 
                                    Inclosure Protection Type For Which Designedgeneral purpose 
- 
                                    Cubic Measure55.319 cubic inches 
- 
                                    Unthreaded Mounting Hole Diameter0.188 inches nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps14000.0 ac all locations and 10000.0 dc all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Length5.250 inches nominal 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.540 maximum at 200 pct all locations 
- 
                                    Case Materialplastic 
- 
                                    Body Height3.187 inches nominal 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    