IN10-1654A2
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
IN10-1654A2
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Maximum Temp Rise25.0 deg celsius 
- 
                                    Inclosure Typeencased 
- 
                                    Vibration Resistance Range In Hertz+10.0/+100.0 
- 
                                    Full Load Insertion Loss Frequencies In Megahertz2.0 and 0.15 and 100.0 
- 
                                    Body Outside Diameter0.570 inches maximum 
- 
                                    Body Surface Treatmenttin 
- 
                                    Functional Terminal Type And Quantity1 wire lead output 2nd function 
- 
                                    Overall Length2.060 inches maximum 
- 
                                    Body Length1.190 inches nominal 
- 
                                    Maximum Voltage Drop Per Function1.0 volts ac blank and 1.0 volts dc blank 
- 
                                    Body Materialmetal 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Operating Current Rating Per Function In Amps1.5 blank 
- 
                                    Output Impedance Per Function W/Source Across Input50.0 ohms blank 
- 
                                    Operating Temp Range-65.0/+85.0 deg celsius 
- 
                                    Source Impedance Rating Per Function50.0 ohms blank 
- 
                                    Full Load Minimum Insertion Loss At Specified Frequency In Decibels20.0 and 50.0 and 60.0 
- 
                                    Nominal Thread Size0.312 inches 
- 
                                    Functional Terminal Type And Quantity1 wire lead input 1st function 
- 
                                    Mounting Facility Screw Thread Series Designatorunf 
- 
                                    Style Designatorround terminal/terminals on opposite surfaces 
- 
                                    Load Impedance Per Function50.0 ohms blank 
- 
                                    Input Impedance Per Function W/Load50.0 ohms blank 
- 
                                    Operating Voltage Rating And Type Per Function115.0 volts ac blank and 400.0 volts dc blank 
- 
                                    Power Line Frequency Rating Per Function In Hertz20.0 blank 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    