177B144P1
Coils and Transformers
TRANSFORMER,POWER
177B144P1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Reliability Indicator
not established
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal
 - 
                                    
Winding Shielding Method
internal shield grounded to inclosure
 - 
                                    
Body Length
3.844 inches nominal
 - 
                                    
Body Height
3.688 inches nominal
 - 
                                    
Inclosure Type
fully inclosed
 - 
                                    
Mounting Method
threaded stud
 - 
                                    
Winding Function And Quantity
1 primary and 6 secondary
 - 
                                    
Special Features
case metal material,primary winding 115 v rating,secondary windings rated 5 v at 4 amp,6.3 v at 150 ma,6.3 v at 3.1 amp w/center tap,6.3 v at 5.8 amp w/center tap,175 v at 88.5 ma w/center tap
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal
 - 
                                    
Frequency Rating
400.0 hertz nominal
 - 
                                    
Input-Output Phase Relationship
single phase to single phase
 - 
                                    
Body Width
3.344 inches nominal
 - 
                                    
Mounting Facility Quantity
4
 - 
                                    
Terminal Type And Quantity
18 tab,solder lug
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    