5114-1914-2
Circuit Breakers
CIRCUIT BREAKER
5114-1914-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Mounting Surface To Terminal End Distance2.437 inches nominal 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.875 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.875 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.437 inches nominal 
- 
                                    Arc Quenching Methodair 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Terminal Type And Quantity6 screw 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 all locations 
- 
                                    Body Length2.187 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations 
- 
                                    Manual Actuator Type And Quantity3 push-pull 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3500.0 ac all locations 
- 
                                    Case Materialplastic 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius maximum all locations 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Body Width2.500 inches nominal 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.812 inches nominal 
- 
                                    Reset Methodmanual 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current10.000 minimum at 200 pct all locations and 50.000 maximum at 200 pct all locations 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole70.0 amperes ac all locations 