2625-120
Circuit Breakers
CIRCUIT BREAKER
2625-120
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
End Item Identification
truck, fire/crash p19; teletype, model 28; aircraft, intruder a-6e; truck, tractor (m911 & m746) (het); truck, aircraft crash/structure firefighting (a/332p-19a); shipboard material handling equipment (mhe); meterological equipment; forrestal class cv;
 - 
                                    
~1
aircraft, t-39; cargo system, 463l; nsn 2320-01
 - 
                                    
Actuator Function
reset
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
 - 
                                    
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Mounting Surface To Terminal End Distance
1.251 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
 - 
                                    
Thread Series Designator
uns
 - 
                                    
Overall Length
2.000 inches nominal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 dc single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
 - 
                                    
Body Style
single pole type
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
 - 
                                    
Unpackaged Unit Weight
1.500 ounces
 - 
                                    
Special Features
weapon system essential
 - 
                                    
Body Width
1.250 inches nominal
 - 
                                    
Criticality Code Justification
feat
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    