78-8015-0147-5

Circuit Breakers

CIRCUIT BREAKER

78-8015-0147-5

5925-00-848-2608

5925 - Circuit Breakers

Systec Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 9.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0 all locations

  • Iii Unpackaged Unit Weight

    8.750 ounces

  • Thread Series Designator

    unc

  • Body Length

    2.530 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.760 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 2000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • External Actuator Linkage Arrangement

    one and two linked

  • Terminal Type And Quantity

    4 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    1.520 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.490 inches nominal

  • Pole Quantity

    2

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...