Technical Characteristics
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.359 inches nominal 
- 
                                    Body Length5.250 inches nominal 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.000 inches nominal 
- 
                                    Body Width3.000 inches nominal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations and 5000.0 ac all locations and 5000.0 dc all locations 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Terminal Type And Quantity6 compression 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.000 inches nominal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Boss Height0.218 inches nominal 
- 
                                    Body Height2.687 inches nominal 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current40.000 minimum at 200 pct all locations and fungus resistant and moisture resistant 
- 
                                    Center To Center Distance Between Terminals Parallel To Length4.359 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Nominal Thread Size0.190 inches 
- 
                                    Reset Methodmanual 
- 
                                    Thread Series Designatorunf 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Unpackaged Unit Weight1.812 pounds 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    