CDA 8I
Circuit Breakers
CIRCUIT BREAKER
CDA 8I
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
5.500 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
 - 
                                    
Pole Quantity
1
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
16.3 millimeters nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location and 30.0 dc single location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 ac single location and 600.0 dc single location
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Nominal Thread Size
0.164 inches
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Body Style
single pole type
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
39.98 millimeters nominal
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Mounting Surface To Terminal End Distance
32.5 millimeters nominal
 - 
                                    
Reset Method
automatic
 - 
                                    
Case Material
plastic
 - 
                                    
End Item Identification
3805-01-126-7915
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
 - 
                                    
Body Width
24.14 millimeters nominal
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Overall Length
50.8 millimeters nominal
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
8.0 amperes ac single location and 8.0 amperes dc single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    