29-1029

Circuit Breakers

CIRCUIT BREAKER

29-1029

5925-01-246-0702

5925 - Circuit Breakers

Georator Corporation The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    2.265 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.750 inches nominal

  • Terminal Type And Quantity

    6 quick disconnect, male

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    126.0 all locations

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • End Item Identification

    metering panel model 34-063

  • Unpackaged Unit Weight

    6.600 ounces

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.666 inches nominal

  • Cubic Measure

    12.096 cubic inches

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    2.000 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 nominal at 150 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    37.5 amperes ac all locations and 37.5 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    38.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...