HFD3110L
Circuit Breakers
CIRCUIT BREAKER
HFD3110L
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Thread Series Designator
unc
 - 
                                    
External Actuator Linkage Arrangement
one and two linked and two and three linked
 - 
                                    
Reset Method
manual
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
110.0 all locations
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
4.125 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.063 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 push button and 1 toggle
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Body Width
5.500 inches nominal
 - 
                                    
Unpackaged Unit Weight
4.500 pounds
 - 
                                    
Body Height
3.500 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
6 threaded hole
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Nominal Thread Size
0.164 inches
 - 
                                    
Boss Height
0.125 inches nominal
 - 
                                    
Terminal Type And Quantity
6 screw
 - 
                                    
Trip Release Duty Cycle
continuous all locations
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
 - 
                                    
Actuator Position Designation
between pole one and two and between pole two and three
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
5.063 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    