121B20-B2M
Circuit Breakers
CIRCUIT BREAKER
121B20-B2M
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Style
single pole type
 - 
                                    
Overall Width
0.790 inches nominal
 - 
                                    
Reset Method
automatic
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Nominal Thread Size
0.190 inches
 - 
                                    
Trip Release Duty Cycle
continuous all locations
 - 
                                    
Trip Release Ambient Temp Rating
-40.0 deg fahrenheit minimum all locations and 185.0 deg fahrenheit maximum all locations
 - 
                                    
Part Name Assigned By Controlling Agency
series 12x shortstop circuit breaker,20amp dc
 - 
                                    
Thread Series Designator
unf
 - 
                                    
Body Length
1.240 inches nominal
 - 
                                    
Body Width
0.790 inches nominal
 - 
                                    
Body Height
0.640 inches nominal
 - 
                                    
Case Material
metal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.690 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.196 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.560 inches nominal
 - 
                                    
Boss Height
0.560 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
1.250 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
14.0 dc all locations and 28.0 dc all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1.5 dc all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Trip Release Method
thermal all locations
 - 
                                    
Trip Release Characteristic
time delay all locations
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    